WA-TX-03-R
and WA-RX-03-R |
 |
Regulatory
compliance of the WA-TX-03-R and
the WA-RX-03-R
The WA-TX-03-R and the
WA-RX-03-R are designed for
embedding in other equipment.
(Products incorporating the
WA-TX-03-R and the WA-RX-03-R
are henceforward referred to as
final products.)
The European regulation
applicable to the WA-TX-03-R and
the WA-RX-03-R is the R&TTE
Directive 1999/5/EC.
The WA-TX-03-R and the
WA-RX-03-R are intended to be
used for the Radio Microphones
defined in the ERC/REC 70-03
Annex 10 and for the Wireless
Audio Applications in the ERC/REC
70-03 Annex 13 (EN 301 357*)
The conformity assessment for
the WA-TX-03-R and the
WA-RX-03-R were completed in
accordance with the R&TTE
Directive Annex II (RX) & III (TX)
procedures, and the Declaration
of Conformity is attached to
this manual.
* NOTE:
EN 301 357 defines the equipment
covered by its standard and the
output power limits depend on
the equipment type. The
WA-TX-03-R meets the output
power limits allowed for all
equipment types except for
“in-vehicle cordless” and
“personal cordless”. If the
WA-TX-03-R is used for
“in-vehicle cordless” or
“personal cordless” equipment,
the manufacturer is required to
design the final product within
the specified output power limit
and to perform the conformity
assessment of the final product
to EN 301 357.
Cautions related to
regulatory compliance when
embedding WA-TX-03-R/WA-RX-03-R
1. Antenna for the WA-TX-03-R
The WA-TX-03-R is supplied
without a dedicated antenna and
the user is required to provide
an antenna. The conformity
assessment of the WA-TX-03-R was
performed using Circuit Design’s
evaluation board and antenna
(1/4 lambda lead antenna). We
recommend that you use our
standard antenna (ANT-LEA-02 or
ANT-RIG-02), or an antenna with
equivalent characteristics and
performance. For details about
our evaluation boards and
antennas, refer to
www.cdt21.com or contact us.
If you use an antenna other than
the recommended antenna, further
radio conformity assessment may
be required.
2. Supply voltage of the
WA-TX-03-R
The WA-TX-03-R should be used
within the specified voltage
range (4.2 V to 6.0 V).
3. Enclosure
To fulfill the requirements of
EMC and safety requirements, the
WA-TX-03-R and the WA-RX-03-R
should be mounted on the circuit
boards of the final products and
must be enclosed in the cases of
the final products. No surface
of the WA-TX-03-R and the
WA-RX-03-R should be exposed.
4. Cordless audio transmitter
shutoff
The WA-TX-03-R does not have
automatic transmitter shutoff
function in the module. The
manufacturer of the final
product is required to design
the final product to have such
function in accordance with EN
301 357.
EMC requirements according to
the R&TTE Directive Article 3.1b
The ESD-test (Electro Static
Discharge test) was not
performed on the WA-TX-03-R and
the WA-RX-03-R. The WA-TX-03-R
and the WA-RX-03-R are designed
for embedding in final products
and rely on the enclosures of
the final products to provide
the necessary protection. The
ESD test should be performed on
the final products incorporating
the WA-TX-03-R and the
WA-RX-03-R.
Safety requirements according
to the R&TTE Directive Article
3.1a
The WA-TX-03-R and the
WA-RX-03-R rely on the final
products to provide the
electrical, mechanical, and fire
enclosure requirements.
The nominal supply voltage of
the WA-TX-03-R is 4.2 – 6.0V and
the WA-RX-03-R is 3.0 V – 5.0
VDC. The worst input currents
under normal operating
conditions are 70mA and 45mA
respectively. The final product
should be capable of supplying
these power requirements.
The WA-TX-03-R and the
WA-RX-03-R are entirely SELV (Separated
Extra Low Voltage) when the
supply input from the final
product is SELV, i.e. the
WA-TX-03-R and the WA-RX-03-R
are Class III equipment in which
protection against electric
shock relies on a supply from an
SELV circuit and in which
hazardous voltage is not
generated.
The WA-TX-03-R and the
WA-RX-03-R should be installed
in the final products so that
the required creepage and
clearance distances (within the
final products) are maintained.
Conformity assessment of the
final product
The manufacturer of the final
product is responsible for the
conformity assessment procedures
of the final product in
accordance with the R&TTE
Directive.
As to the conformity assessment
of the R&TTE Directive Article
3.2 (Efficient use of the radio
spectrum), the manufacturer of
the final products incorporating
the R&TTE assessed WA-TX-03-R
and WA-RX-03-R will be exempted
from its conformity assessment
procedures. For details of how
to use the conformity assessment
of the WA-TX-03-R and the
WA-RX-03-R, please consult the
relevant authorities or
accredited certification bodies.
Notification of the final
product
The notification required by R&TTE
Directive Article 6 (4) is not
necessary if the final product
is used in the harmonized
frequency band and is classified
as Class-1 equipment. If the
final product is not used in the
harmonized frequency band and is
classified as Class-2 equipment,
the manufacturer of the final
product has a duty to notify the
relevant radio regulatory
authorities in the countries
where the final product is sold.
Exemption clause
Circuit Design, Inc does not
guarantee the accuracy of the
above mentioned information
about the conformity assessment
and notification of the final
product. Directives, technical
standards, principles of
operation and the like may be
interpreted differently by the
authorities in each country.
Also the national laws and
restrictions vary with the
country. In case of doubt or
uncertainty, we recommend that
you check with the authorities
or official certification
organizations of the relevant
countries |
|
|
Iscrivetevi nella nostra
mailing-list inviando una E-mail
vuota a
click |
|
|
|
|
|
|
Distributore Italia SYLCOM S.r.l. - P.zza Martiri